96 Equipment installation and configuration
Figure 15 "Backplane to I/O panel connections on the IPE module" (page
94)
shows the MMI terminal cable connections for a Carrier Remote IPE
column. Also, refer to
diagram (single RCI configuration)" (page
To connect the MMI terminal, follow the steps in
remote MMI terminal cables" (page
Procedure 17
Installing remote MMI terminal cables
Step
1
2
3
4
Connecting the carrier link to the Remote IPE module
The T1 or E1 carrier links are connected to the I/O panel assembly at
the rear of the IPE module housing the Remote Carrier Interface card.
Carrier links are routed from the telco demarcation point to the Carrier
Remote IPE column for connection to the NT7R59AA Carrier Panel and
the NT7R60AA Carrier/Alarm Panel assembly.
Figure 28 "Remote Carrier IPE module connection
Action
Plug the DB-9 female connector of the NT7R66BA MMI
Cable into the MMI DB-9 male connector on the IPE module
NT7R61AA Remote Maintenance Panel assembly.
Plug the other end of the NT7R66BA MMI Cable DB-25 male
connector into the MMI terminal RS-232 connector. If the MMI
terminal has a male connector, use a compact gender changer
to connect the MMI terminal.
If an distant MMI terminal is connected to the MMI connector
on the Maintenance Panel Assembly over a modem, use the
NT7R66BA MMI Cable and a nullmodem to connect the modem
to the MMI D-9 male connector on the NT7R61AA Remote
Maintenance Panel Assembly.
For multiple Carrier Remote IPE modules at a single site, use an
A/B/C switch box to connect each MMI DB-9 male connector on
the Maintenance Panel assembly to a single MMI terminal.
To do this, use the NT7R66BA MMI Cable between the A/B
switch box connector C and the MMI connector on each IPE
module. Use a DB-25M/ DB-25M straight through cable to
connect the A/B switch box connector A to the MMI terminal.
Note:
"Connection diagrams and external connectors pin
assignment" (page 197)
assignment for the SDI port, the MMI terminal, the carrier
links, and the external alarms.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
200).
Procedure 17 "Installing
96).
provides the external connectors pin
--End--