Nortel Communication Server 100 Manual page 123

Carrier remote ipe fundamentals
Table of Contents

Advertisement

Carrier 0 equipped
Carrier 1 equipped
Carrier 2 equipped (not a spare)
Alarms enabled (automatic clearing of Carrier Alarm Indication)
Before configuring the Carrier Remote IPE, check the current (default)
configuration and determine whether the communication is established
with the distant end. The S A and the S C commands affect the distant
end automatically only when the distant end is communicating.
To display the configuration parameters, execute the D C command on the
MMI terminal. This is an example of what the MMI terminal might display:
CRI::> D C
CRI Remote IPE S/N L1105-A4 Software Version 1.00 8/17/95 10:48
Local Site
Alarm Enabled: YES Self Clearing Enabled: YES
Sparing Enabled/Disabled: Enabled
All Link Maps Normal
Alarm Level 1 Threshold Value E-6 Threshold Duration (in seconds) 1
Alarm Level 2 Threshold Value E-5 Threshold Duration (in seconds) 1
Alarm Level 3 Threshold Value E-4 Threshold Duration (in seconds) 1
Frame Slip Alarm Level Threshold 100 Threshold Duration (in hours) 2
Current DIP Switch S1 Settings (s1-s8) OFF OFF ON ON OFF ON ON
OFF
Current DIP Switch S11 Settings (s1-s8) OFF OFF OFF ON ON OFF OFF
OFF
Unless there is a particular reason to change the default parameters, leave
them unchanged.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Configuring the Carrier Remote IPE 123