128 Equipment installation and configuration
Note:
of the Carrier Remote Interface Alarm Log with error messages in the
local system History File.
Verifying carrier link connections at the remote site
When all the carriers are connected and equipped, all carrier alarm LEDs
might be turned OFF and the signaling across the link works even though
there might be a mismatch in carrier link connection between the local
and remote ends. However, the voice and data connections might not
work due to the scrambling of the time slots, which are assigned to specific
carriers and cannot be used by other carriers. Carrier Test 1 might not
show any errors under these conditions.
Note:
card faceplate ENB/DIS switch is set to DIS. Carrier clocking is enabled
when the switch is set to ENB. Carrier alarms can clear even while the
Local Carrier Interface card is not software enabled when the switch is
set to ENB.
All equipped carriers have been previously connected and configured at
the local site and the carrier circuit ID recorded for each link 0-2. All carrier
facilities (carrier links) should have been installed and tested by the carrier
network provider up to the demarcation point at both ends.
To insure that all equipped carrier links are connected to their
corresponding I/O panel connectors at the remote site, identify, test, and
tag each carrier link individually as described in .
Procedure 29
Identifying, testing, and tagging carrier links
Step
1
Current Date 8/10/9518/11/95
Current Date 8/11/95
CRI::> S N
Change Site Name (Yes or No) Y
Enter Site Name SFO
Time and date should be configured correctly to allow correlation
All carriers show Out of Frame alarm if the Local Carrier Interface
Action
Configure all equipped carrier links by executing the S C (Set
Configuration) command.
Any unused carrier links must be configured as "unequipped"
to prevent the carrier alarm LED from being constantly ON.
Configure carrier #2 as spare or primary (not spare). Default
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Enter correct date at the
cursor, if required.
Set site name
Change name or add name
if not previously entered.