86 Equipment installation and configuration
8
Carrier Remote IPE column installation
To complete the installation of the Carrier Remote IPE column equipment:
install the Carrier Remote IPE column
install the cards into the IPE module
install the cable assemblies from the I/O panel to the backplane
connect carrier links to the carrier panel assembly
configure the carrier equipment using overlays and MMI commands
Note:
the factory with cards already in their respective card slots. The only
exception is the power supply, which is packaged separately and must
be installed at the site.
Installing the Carrier Remote IPE column
The column is normally assembled in the factory with cards already
installed and the cable already connected between the backplane
connector and the I/O panel at the rear of the IPE module.
If the column is not assembled in the factory, it is necessary to install the
modular column (floor-standing column) at the remote site. To do this,
follow the instructions in Communication Server 1000M and Meridian
1 Large System Installation and Commissioning (NN43021-310) (). It
describes how to install the pedestal, the IPE module, and the top cap, and
how to connect the power, the internal and external communication cables,
and subscriber loops.
To install the Power Fail Transfer Unit (PFTU) to the Carrier Remote IPE
column, follow the instructions in Communication Server 1000M and
Meridian 1 Large System Installation and Commissioning (NN43021-310)
().
Installing cards into the Remote IPE module
The following steps describe how and where to install the NT7R52 Remote
Carrier Interface card and other IPE cards in the Remote IPE module.
Although the cards usually are shipped installed from the factory, this
document provides step-by-step card installation, which should be followed
when additional IPE cards are installed or defective cards are replaced.
To install cards in the Remote IPE Module, follow the steps in
13 "Installing cards into the Remote IPE module" (page
Secure the carrier link cables with tie-wraps as appropriate.
All Carrier Remote IPE modules or cabinets are pre-installed in
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
--End--