Nortel Communication Server 100 Manual page 187

Carrier remote ipe fundamentals
Table of Contents

Advertisement

.
Appendix
System messages
Table 31 "System error messages related to the CRI" (page 187)
CRI-related system messages displayed or printed on the system and MMI
terminal or TTY.
Note:
if alarms are disabled by the MMI command A D (Alarm Disable).
CRInnnn messages are suppressed for a given carrier link if it is
UNEQUIPPED by the MMI command S C (Set Configuration).
Table 32 "Remote Carrier Interface HEX error codes for self-test" (page
190)
Remote Carrier Interface card faceplate.
Table 31
System error messages related to the CRI
Error Code
Message description
BSD805/806
Superloop timeslot not available. Check the timeslot allocation for each T1/E1
carrier.
NPR0019
LCI did not respond to the request of disable/enable the RTE superloop.
Ensure that the LCI is installed and that the ENL/DIS switch is in ENL position.
NWS0019
LCI did not respond to the request of disable/enable the superloop. Ensure
that the LCI is installed and that the ENL/DIS switch is in ENL position.
PWRxxxx
Carrier Remote IPE cabinet system monitor emulation.
SCH6575
REM_IPE package is not equipped.
SCH6576
Missing LCI software from disk.
SCH6577
Cannot change SUPT in the defined superloop. Superloop is not disabled.
CRIabcd
Where a=1 for local and 2 for remote, 3 for external, b= carrier 0, 1, or 2,
c= alarm lever 1, 2, or 3, and d= 0 for bit error, 1 for frame slip, 2 for loss of
signal, 3 for blue alarm, 4 for out-of-frame, 5 for within threshold, and 6 for
MMI enabled. That is, carrier equipped using MMI configuration commands.
This is shown in subsequent system error messages.
CRInnnn messages are suppressed for a given superloop
lists HEX codes displayed by the alphanumeric display on the
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.