16 Carrier Remote IPE product description
Table 4
Carrier Remote IPE wall-mounted cabinet hardware list
Component
NT7R52 Remote
Carrier Interface card
NTIP70 Main Cabinet
Assy
NTBK70 Expansion
Cabinet
NTAK27 Pedestal for
the Cabinet (optional)
NT7R66BA MMI Cable
NT7R67EA Coaxial
Interface Adapter
Cable
NT7D68DA Remote
Maintenance Cable
Assy to Cabinet
NT7R86AA Auxiliary
Alarm Cable Assy
NT7R87AA T1 CSU
Cable Kit
NT7R94AA Remote
Cabinet Cable Assy
Description
Remote Carrier Interface card (installed in the Remote IPE module or
the Remote IPE cabinet).
Main wall-mounted (or pedestal mounted) Carrier Remote IPE cabinet.
The NT1P70 consists of the NT1P60 Main Cabinet and mounting
hardware.
Expansion Carrier Remote IPE cabinet. Expands the capacity by six IPE
cards. Requires the NTAK1204 Inter-Cabinet cable to connect to the
main cabinet.
This pedestal allows the Carrier Remote IPE cabinets to be
floor-mounted.
This is a 9.75 m (32 ft) DB-9 female to DB-25 male cable. Connect
the MMI terminal to the DB-9 male MMI connector on the NT7R61AA
Maintenance Panel Assy.
Cable with one 8-pin modular plug that plugs into the NT7R68CA Remote
Carrier/Alarm Panel Assy 8-pin modular jack and two BNC connectors
that plug into the carrier link BNC connectors.
This cable assembly connects the Remote Carrier Interface to the I/O
bracket on the wall-mount IPE cabinet for system monitor and MMI
connections. Consists of the NT7R68NA cable that connects with P1
DB-9 male connector to the TTY connector on the backplane and is
already connected to the NT7R61AA Maintenance Panel assembly
with the DB-15 male P2 cable connector. The DB-15 female P3
cable connector must be plugged into the NT7R60AA Carrier/Alarm
Panel assembly connector during cable installation. The NT7R61AA
Maintenance Panel assembly provides a DB-9 male MMI port connector.
Refer to Appendix C,
Figure 29 "Remote Carrier IPE cabinet connection
diagram (single RCI configuration)" (page
Connects auxiliary alarms, such as customer external alarms, to the
DB-15HD female Alarm connector on the NT7R60AA Carrier/Alarm
Panel. The cable is 9.75 m (32 ft) long.
This cable kit consists of a DB-15M/RJ-48 adapters and a 9.75 m (32
ft) RJ-48 to RJ-48 cable. The appropriate adapter is used to connect to
a CSU and the cable is used to connect the adapter to the NT7R59AA
Carrier Panel Assy and the NT7R60AA Carrier/Alarm Panel Assy RJ-48
connector.
This Remote Cabinet Cable Assembly consists of the NT7R68CA
Remote Carrier/Alarm Cable Assy, the NT7R68DA Remote Maintenance
Cable Assy, and the NT7R62AA Bracket. All components are preinstalled
in the factory.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010