Carrier Remote IPE Module I/O panel connector selection
When installing the carrier remote panel assemblies for the Remote Carrier
Interface card at the rear of the IPE Module, use the recommendations
listed below:
Left I/O Panel:
Install the NT7R59AA Carrier Panel Assembly into the J4 connector
cutout.
Install the NT7R60AA Carrier/Alarm Panel Assembly into the J5
connector cutout.
Right I/O Panel:
Install the NT7R61AA Maintenance Panel Assembly into the J2
connector cutout.
Locate connector cutouts that are 2.25 inches high on the I/O panel at
the rear of the module containing the Local Carrier Interface card.
Note:
Some old network modules have 2.00-inch connector
cutouts, which are not suitable for carrier panel assembly installation.
To be able to install these carrier panel assemblies, you must
replace the module's I/O panels with the latest version that have
2.25-inch connector cutouts.
Use the left-hand-side I/O panel connector cutouts for the Local Carrier
Interface card carrier panel assemblies installation to avoid cable
congestion on the right-hand side, if possible.
Use side-by-side connector cutouts for the Local Carrier Interface
card panel assemblies starting at the top of the I/O panel. This avoids
obstruction of internal cable-way and associates the carrier panel
assemblies with their respective Local Carrier Interface cards.
Note:
The current left-hand I/O panel for the Network Module has
the highest numbered connector position (J38) in the lower left-hand
corner. Older left-hand-side I/O panels on the Network Modules
have the highest numbered connector position (J28) in the lower
left-hand corner.
This older Network Module Universal I/O panel such as P075058
can accommodate only one set of carrier panel assemblies, which
correspond to one Local Carrier Interface card. Side-by-side connector
cutouts suitable for carrier panel assembly installation are:
Left I/O Panel:
For the first Local Carrier Interface card, install the NT7R57AA
Carrier Panel Assembly into the I/O panel connector cutout J17 and
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Pre-installation preparation 61