Nortel Communication Server 100 Manual page 125

Carrier remote ipe fundamentals
Table of Contents

Advertisement

lists MMI commands used to display and configure carrier parameters
such as setting alarm thresholds, setting time and date, configuring carrier
links, connecting to the SDI port, and testing the carriers and interfaces to
the carrier link.
Table 24
MMI commands used in setting the carrier parameters
Command
Description
D C
Display configuration. Displays current configuration of the
Local and Remote Carrier Interface cards.
D C D
Display configuration distant. Displays current configuration of
distant Local and Remote Carrier Interface cards.
D S
Display status. Displays near-end carrier status.
D S D
Display status distant. Displays far-end carrier status.
L
Log into the MMI terminal when the system has one Local
Carrier Interface card. The password is M1LINK.
L sl
Log into a specific superloop when the system has more than
one Local Carrier Interface card daisy-chained in the network
module. Refer to to see the path L (address). The password
is M1LINK.
S A
Set carrier alarm threshold and duration parameters
S T
Set time or verify current time
S D
Set date or verify current date
S C
Set configuration
S N
Set site name and superloop
HOST or HO
Terminal in Host SDI mode. The password is HOST.
@@@
Terminates the Host SDI connection
T
Specifies a test from 1 to 5 to be run on the equipment
Q
Logs the terminal user out
To configure the carriers and specify carrier 2 as a spare carrier:
CRI > L
Enter Password > M1LINK
CRI:: >
CRI::> S C
Equipped carrier 0 (Yes or No) Y
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Configuring the Carrier Remote IPE 125
To login to the MMI terminal
Password is M1LINK
Prompt requesting an MMI
command
To set carrier parameters
Enable carrier 0. Enter Y to enable
or N to disable.