Nortel Communication Server 100 Manual page 117

Carrier remote ipe fundamentals
Table of Contents

Advertisement

Table 17
To change the system configuration record (LD 17) (cont'd.)
Prompt
Response
CEQU
YES
MPED
8D
Table 18
To configure the Remote Carrier IPE site (LD 97)
REQ
CHG
TYPE
XPE
SUPL
0-252
XPEC
2
LOC
SCLARA
RGTP
(8) 16
After defining the new Peripheral Controller (RCI), define the superloop
for the Local Carrier Interface card.
Table 19
To define a carrier superloop
Prompt
Response
REQ
CHG
TYPE
SUPL
0–252
SUPL
SLOT
(L) R
SUPT
CARR
1–99
XPEC
To configure the Carrier Remote IPE superloop and the Carrier Remote
IPE column or cabinet site, load Configuration Record Program LD 17 and
Configuration Record Program LD 97.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Configuring the Carrier Remote IPE 117
Description
Change equipment
Peripheral density
Remote Carrier Interface definition
Remote Peripheral Controller (RCI) ID
Prints superloop type and number
Controller ID number.
remote site location example. Use any six
alphanumeric characters to identify the remote
site.
Number of concurrent ringers. Change to 16
unless ringing generator is an older type.
Description
Adding a new Local Carrier Interface card
Adding a superloop for the Local Carrier
Interface card.
Superloop number
Superloop card side for the Local Carrier
Interface card, where L (left) is default position.
Carrier superloop type. Prompted when
REM_IPE 286 software package is installed.
Remote Carrier Interface card (Controller ID
number) previously equipped. Defaults to shelf
0 segment 0-3 for
SUPT = CARR

Advertisement

Table of Contents
loading

Table of Contents