Procedure 37
Checking the Local Carrier Interface card status
Step
Action
1
Log in on the maintenance terminal as described in
system maintenance programs" (page
2
At the > prompt, type LD 32 and press the Enter key to access
the Maintenance and Diagnostic Program LD 32.
3
Type STAT sl and press the Enter key, where sl is the
superloop number.
It shows the highest alarm value of both cards being checked.
The far-end alarm does not show at the near end.
LD 32
NPR000
STAT sl
CARR
0
1
2
Note: This example shows 3 primary carriers and no spare, all
carriers without alarm, and are available for New Data Calls. No calls
in progress.
LD 32
NPR000
STAT sl
CARR
0
1
2
Note: This example shows 3 primary carriers and no spare, carrier 0
in los-of-signal (LOS) fault status.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Carrier Remote IPE fault isolation and correction 163
CALS
TTSA
0
21/21
0
21/21
0
21/21
CALS
TTSA
3
0/21
0
21/21
0
21/21
"Using
154).
NND
SPARED
NO
N/A
NO
N/A
NO
N/A
NND
SPARED
YES
N/A
NO
N/A
NO
N/A