3
4
Replacing Carrier Remote IPE cards
If after completing troubleshooting, it is determined that one or more
Carrier Remote IPE cards are defective, remove the defective cards and
replace them with spares.
When inserting a spare Local Carrier Interface card or a Remote Carrier
Interface card into the module or Carrier Remote IPE cabinet, observe
the card LED (the uppermost LED on the faceplate) to determine if the
card passed the self-test. Package and ship the defective cards to an
authorized repair center.
CRI:>L
Enter Password: M1LINK
CRI::>L
CRI::>T
Test 1: Online Test
Test 2: Near End Loopback Test
Test 3: Remote Loopback
Test 4: Network Loopback
Test 5: Loop only
(1, 2, 3, 4, 5, or S to cancel): 1
Which carrier (0, 1, or 2): 2
Carrier Currently ENABLED
Enter Duration of Test (1-98 minutes, 0= once,
99= forever): _ Test will not interfere with calls in
progress
Hit Q to quit or any key to continue
Near End Testing
Carrier 2 Test 1 Completed. Total Test 1 Total Errors
0.
If an off-line test is selected, the user is prompted with:
This test will interfere with calls currently in
progress, continue ?: (Y or N): _
Check the results of the test and correct the identified fault.
Replace the faulty card or fix the problem in the carrier link if this
is indicated in the test report.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Replacing Carrier Remote IPE cards 181
--End--