Carrier remote ipe fundamentals
Table of Contents

Advertisement

116 Equipment installation and configuration
Table 16
CFN configuration data print format- find unused superloop
Note:
loadware is downloaded into the Local and Remote Carrier Interface
cards. PSDL is initiated upon:
Initialization (INIT).
ENXP after power reset or the Local or Remote Interface card.
ENXP of the Remote Carrier Interface card by adding peripheral
software version parameter after the Peripheral Controller ID.
ENLL of the Local Carrier Interface card by adding the PSW version
parameter after the SUPC number.
To change the system configuration record and to configure the Remote
Carrier Interface at the Carrier Remote IPE column or cabinet site, load
Configuration Record Program LD 17 and Configuration Record Program
LD 97.
Table 17
To change the system configuration record (LD 17)
CEQU
MPED
SD/DD/4D/8D
xxx xxx xxx...
TERM
REMO
xxx xxx xxx...
xxx xxx xxx...
SUPL
xxx xxx xxx
SUPC
PKG
REM_IPE
286
PSWV
XPEC:
XX
LCRI:
XX
Parameter Software Download (PSDL) ensures that the latest
Prompt
Response
REQ
CHG
TYPE
CFN
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Prints maximum peripheral density for the
system (use 8D for systems with IPE)
Prints all terminal loops
Prints remote EPE loop numbers configured
in LD 17
Lists all local Superloop Network card
superloop numbers
Lists all carrier remote superloops when
REM_IPE 286 software package is installed
Software package for Carrier Remote IPE
Software version number
Software version number downloaded to
Local Carrier Interface cards. A forced
PSDL is initiated upon execution of the
ENLL and ENXP commands (Note).
Description
Change the configuration record
Configuration record