5.2.2 Tuning-less Levels Setting (Fn200) Procedure

To ensure safety, perform tuning-less function in a state where the SERVOPACK can come to an emergency stop at
anytime.
The following procedure is used for setting the tuning-less levels.
Setting tuning-less Levels is performed from the digital operator (optional), or SigmaWin+.
The operating procedure from the Digital Operator is described here.
For the basic operation of the digital operator, refer to
tor (SIEP S800000 55).
(1) Before Performing Tuning-less Function
Check the following settings before performing the tuning-less function, or otherwise "NO-OP" will be dis-
played during the tuning-less operation.
• The tuning-less function must be enabled. (Pn170.0 = 1)
• The write prohibited setting (Fn010) must not be set.
(2) Operating Procedure with Digital Operator
Step
Display after Operation
1
2
3
4
2nd notch filter
CAUTION
Σ
-V series User's Manual, Operation of Digital Opera-
Keys
Press the
Key to view the main menu for the
utility function mode.
Use the
or
select Fn200.
Press the
Key to display the tuning-less mode
setting screen.
Notes:
• If the display does not switch and "NO-OP" is dis-
played, the write prohibited setting is set in Fn010.
Change the setting in Fn010 and press the key
again after enabling writing.
• If the response waveform causes overshooting or if
the mass ratio exceeds 30 (i.e., outside the scope of
product guarantee), press the
the mode setting to 2.
• If a high-frequency noise is heard, press the
Key and change to the mode setting to 0.
• The tuning mode can be also changed in Pn170.3.
Press the
Key to display the tuning level setting
screen.
Press the
or
Select the tuning level from 0 to 4. The larger the
value, the higher the gain is and the better response
performance will be. (The factory setting is 4.)
Notes:
• Vibration may occur if the tuning level is too high.
Lower the tuning level if vibration occurs.
• If a high-frequency noise is heard, press the
Key to automatically set a notch filter for the vibra-
tion frequency.
• The tuning level can be also changed in Pn170.2.
5.2 Tuning-less Function
Operation
Key to move through the list,
Key and change
Key to select the tuning level.
5
5-13

Hide quick links:

Advertisement

Table of Contents
loading