(2) Operating Procedure
Follow the steps below to perform the gain adjustment of analog monitor output.
Step
Display Example
1
2
3
4
5
6
7
6.9 Gain Adjustment of Analog Monitor Output (Fn00D)
Keys
Press the
Key to view the main menu for the util-
ity function mode.
Use the
or
select Fn00D.
Press the
Key. The display is switched to the
execution display of Fn00D.
Note:
If the display is not switched and "NO-OP" is dis-
played in the status display, the Write Prohibited Set-
ting (Fn010 = 0001) is set. Check the setting and
reset. (Refer to 6.12.)
Press the
or
ment width of CH1 (force reference monitor).
After the gain adjustment of CH1, press the
The cursor moves to CH2 (motor speed monitor)
side.
Press the
or
ment width of CH2.
After having completed the adjustment both for CH1
and CH2, press the
The adjustment results are saved in the SERVO-
PACK. After the saving is completed, "DONE" is
displayed in the status display.
Press the
Key to return to the Utility Function
Mode main menu.
Operation
Key to move through the list,
Key to adjust the gain adjust-
Key.
Key to adjust the gain adjust-
Key.
6
6-19