Parameter
Name
No.
Application Function Select Switch C
4th
3rd
2nd
digit
digit
digit
n.
Pn00C
Application Function Select Switch D 0000 to 0001
4th
3rd
2nd
digit
digit
digit
n.
Pn00D
Pn010
Axis Address Selection
Application Function Select Switch
80
4th
3rd
2nd
digit
digit
digit
n.
Pn080
Setting
Range
0000 to 0111
1st
digit
Selection of Test without Motor
0
Disables Test without motor.
1
Enables Test without motor.
Reserved (Do not change.)
Encoder Type for Test without Motor
Incremental linear scale
0
Absolute linear scale
0
Reserved (Do not change.)
1st
digit
Stand-alone Mode (Test Operation) Selection
0
Enables connection with the command option module.
1
Disables connection with the command option module.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
0000 to 007F
0000 to 1111
1st
digit
Hall Sensor Selection
Enables selection.
0
Disables selection.
1
Motor Phase Selection
0
Sets phase A lead as phase sequence of U, V, W.
Sets phase B lead as phase sequence of U, V, W.
1
Reserved (Do not change.)
Calculation Method for Maximum Speed or Divided Output Pulses
0
Determines divided output pulses with fixed maximum speed.
Determines maximum speed with fixed divided output pulses.
1
Factory
When
Units
Setting
Enabled
0000
After restart
0000
After restart
0001
After restart
0000
After restart
9.1 List of Parameters
Reference
Classification
Section
Setup
(Refer to 4.3.3)
(Refer to 4.3.3)
Setup
Setup
Setup
9
9-7

Hide quick links:

Advertisement

Table of Contents
loading