YASKAWA Σ-V Series User Manual page 202

Ac servo drives; linear motor command option attachable type
Hide thumbs Also See for Σ-V Series:
Table of Contents

Advertisement

5 Adjustments
5.9.2 Using the Mode Switch (P/PI Switching)
Using the Position Error Pulse Level to Switch Modes
With this setting, the speed loop is switched to P control when the position error pulse exceeds the value set in
Pn10F.
This setting is effective with position control only.
<Example>
In this example, the mode switch is used to reduce the settling time. It is necessary to increase the speed loop
gain to reduce the settling time. Using the mode switch suppresses overshooting when speed loop gain is
increased.
Increase speed loop gain.
5-64
Speed reference
Speed
Position
error pulse
Pn10F
PI
Without Mode Switching
Speed reference
Motor
speed
Long settling time
Overshoot
Motor
speed
Overshoot
Motor
speed
Time
P Control
PI Control
With Mode Switching
Motor
speed
Time
Motor
speed
Time
Settling time
Time

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents