(2) Related Parameters
The Easy FFT related parameters are listed below. These parameters will be automatically set and the user
need not set them manually.
Parameter
n.
0
n.
1
Pn408
n. 0
n. 1
1st Notch FIlter Frequency
Pn409
Setting Range
50 to 5000
2nd Notch FIlter Frequency
Pn40C
Setting Range
50 to 5000
Sweep Force Reference Amplitude
Pn456
Setting Range
1 to 800
Meaning
Disables 1st notch filter. (Factory setting)
Uses 1st notch filter.
Disables 2nd notch filter. (Factory setting)
Uses 2nd notch filter.
Setting Unit
1 Hz
Setting Unit
1 Hz
Setting Unit
1%
When Enabled Classification
Immediately
Speed
Position
 
Factory Setting
When Enabled
5000
Immediately
Speed
Position
 
Factory Setting
When Enabled
5000
Immediately
Speed
Position
 
Factory Setting
When Enabled
15
Immediately
6.19 EasyFFT (Fn206)
Setup
Force
Classification
Tuning
Force
Classification
Tuning
Force
Classification
Tuning