9 Appendix
9.1.2 Parameters
Parameter
No.
Input Signal Selection 2
4th
digit
n.
Pn50B
Pn50C
Reserved (Do not change.)
Pn50D
Reserved (Do not change.)
9-16
Name
3rd
2nd
1st
digit
digit
digit
N-OT Signal Mapping
0
Valid when CN1-13 input signal is ON (L-level).
1
Valid when CN1-7 input signal is ON (L-level).
2
Valid when CN1-8 input signal is ON (L-level).
3
Valid when CN1-9 input signal is ON (L-level) .
4
Valid when CN1-10 input signal is ON (L-level).
5
Valid when CN1-11 input signal is ON (L-level).
6
Valid when CN1-12 input signal is ON (L-level).
7
Reverse run prohibited.
8
Reverse run allowed.
9
Valid when CN1-13 input signal is OFF (H-level).
A
Valid when CN1-7 input signal is OFF (H-level).
B
Valid when CN1-8 input signal is OFF (H-level).
C
Valid when CN1-9 input signal is OFF (H-level).
D
Valid when CN1-10 input signal is OFF (H-level).
E
Valid when CN1-11 input signal is OFF (H-level).
F
Valid when CN1-12 input signal is OFF (H-level).
Reserved (Do not change.)
/P-CL Signal Mapping
0 to F Same as N-OT signal mapping
/N-CL Signal Mapping
Same as N-OT signal mapping
0 to F
Setting
Factory
Units
Range
Setting
0000 to FFFF
8882
8888
8888
When
Classification
Enabled
After restart
Setup
(Refer to 4.2.3)
Reference
Section