YASKAWA Σ-V Series User Manual page 306

Ac servo drives; linear motor command option attachable type
Hide thumbs Also See for Σ-V Series:
Table of Contents

Advertisement

9 Appendix
Parame-
Factory
ter
Setting
Pn561
100%
Pn580
10
Pn581
20 mm/s
Pn582
10 mm/s
Pn583
10 mm/s
Pn584
10000 mm/s
Pn585
50 mm/s
Pn586
0%/maxvel
Pn587
0000
Pn600
0 W
Pn601
0
Pn800
to
0
Pn95F
9-28
Name
Overshoot Detection Level
Reserved Parameter
Zero Speed Level
Speed Coincidence Signal Output
Width
Brake Reference Output Speed Level
Speed Limit Level at Servo ON
Program JOG Movement Speed
Motor Running Air-cooling Ratio
Polarity Detection for Absolute Scale
Selection
Regenerative Resistor Capacity
Reserved Parameter
Reserved Parameter
When
Enabled
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents