Control Menu; Tab; Message Recognizer - Lightware UMX-TPS-TX120 User Manual

Hdbaset multimedia extender
Hide thumbs Also See for UMX-TPS-TX120:
Table of Contents

Advertisement

 
5. Software Control - Lightware Device Controller
5.9. Control Menu
5.9.1. RS-232 Tab
RS-232 Tab in the Control Menu
The following settings and functions are available on the local and TPS link RS-232 port:
RS-232 mode: Control, Pass-through, and Command Injection (for more details about serial interface
modes see the
Technical Background
Baud rate: 4800, 7200, 9600, 14400, 19200, 38400, 57600, 115200;
Data bits: 8 or 9;
Parity: None, Odd, or Even;
Stop bits: 1, 1.5, or 2;
Command injection: enable or disable;
Command injection port number;
Control protocol: LW2 or LW3;
Message sending via serial port;
Reloading factory defaults (see factory default settings in the

ATTENTION!
The RS-232 Operation mode is mirrored on the Local and TPS out serial port. The other
settings can be adjusted separately on the two ports.
section);
Factory Default Settings
section).
#rs232 #rs-232 #serial #commandinjection
Applied firmware packages: (UMX-TPS): v1.5.0b4 | (WP-UMX-TPS): v1.4.0b8 | (FP-UMX-TPS): v1.4.0b8 | LDC software: v2.5.6b2
UMX-TPS-TX100 series – User's Manual
5.9.2. Message Recognizer
DIFFERENCE:

This
feature
UMX-TPS-TX140-Plus,
WP-UMX-TPS-TX130-US models.
The device can analyze and store the received serial data.
For more information see the
Check the Enable message recognizer on this port option to
switch the recognizer on.
Delimiter sequence text box is for setting the delimiter
string in hex format. When this string is detected in
the incoming serial data, the device saves the RS-232
message data from the first bit till the delimiter (or the
data between the two delimiters).

INFO:
0D0A is the factory default value, this is the
hexadecimal code of Carriage Return and Line Feed.
LW3 protocol commands end with this formula, so
the default value support the recognition of the LW3
commands and the stored changes automatically.
If the Timeout is enabled and set, the received data is
saved when the timeout is elapsed after the last received
message.
In Received messages box shows the last received
and stored message in Text (RECOGNIZER.Rx), Hex
(RECOGNIZER.RxHex), and Hash (RECOGNIZER.Hash)
format. The Hex and Hash contains the delimiter.
Press the Clear button to erase this storage.
Clicking on Reload restores the

ATTENTION!
The Message recognizer settings are mirrored on the Local and TPS out serial port.

INFO:
Message recognizer operates independently of the RS-232 mode.
is
available
in
UMX-TPS-TX140K
and
RS-232 Recognizer
section.
Factory Default Settings
of the recognizer.
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Umx-tps-tx130Umx-tps-tx140Umx-tps-tx140kUmx-tps-tx140-plusFp-umx-tps-tx120Fp-umx-tps-tx130 ... Show all

Table of Contents