Control Menu - Lightware HDMI-TPS-RX110AY Series User Manual

Hdbaset multimedia extender
Table of Contents

Advertisement

 
5.SoftwareControl-LightwareDeviceController
5.7. Control Menu
5.7.1. RS-232
Thefollowingsettingsandfunctionsareavailable(bothonlocalandTPSserialports):
Operationmode:Pass-through,Control,orCommandInjection(formoredetailsaboutserialinterface
modes see the
Serial Interface
section);
Baudrate:4800,7200,9600,14400,19200,38400,57600,115200;
Databits:8or9;
Parity:None,Odd,orEven;
Stopbits:1,1.5,or2;
Commandinjection:enableordisable;
Command injection port number;
Controlprotocol:LW2orLW3;
Message sending via serial port;
Reloading factory defaults (see factory default settings in the
ATTENTION!

Operation mode of the local and TPS serial ports can be set together only. It means if you set the
local RS-232 port to Control mode, the TPS serial link will be changed to Control mode either automatically.
ATTENTION!

IfthereceiverisconnectedtoaTPS2outputboardofamatrixframe,theRS-232configuration
settings (baud rate, data bits, e.t.c.) will not be changeable on the receiver side.
#rs232 #rs-232 #serial #commandinjection #message
RS-232 tab in Control menu
Factory Default Settings
Appliedfirmwarepackage:v1.4.0 | LDCsoftware:v2.4.0b3
HDMI-TPS-RX110AY series – User's Manual
Message Recognizer

DIFFERENCE:
HDMI-TPS-RX110AY-Plus model can analyze and
store the received serial data. For more information
see the
RS-232 Recognizer
Put a tick to Enable message recognizer on this port to
switch the recognizer on.
Delimiter sequence text box is for set the delimiter
stringinhexformat.Whenthisstringisdetected
in the incoming serial data, the device saves the
RS-232 message data from the first bit, until the
delimiter (or the data between the two delimiters).
INFO:

0D0A is the factory default value, this is
the hexadecimal code of Carriage Return and
Line Feed. LW3 protocol commands ended
with this formula, so the default value support
therecognitionoftheLW3commandsandthe
stored changes automatically.
If the Timeout is enabled and set, the received data
is saved when the timeout is elapsed after the last
received message.
In Received messages box shows the last received
and stored message in Text (RECOGNIZER.Rx), Hex
(RECOGNIZER.RxHex), and Hash (RECOGNIZER.
Hash) format. The Hex and Hash contains the
delimiter.
Press the Clear button to erase this storage.
Clicking on Reload restores the

ATTENTION!

INFO:
Message recognizer operates independently of the RS-232 mode.
#recognizer #rs232recognizer #rs-232recognizer
section).
This feature is available only in HDMI-TPS-RX110AY-Plus model.
section.
Factory Default Settings
of the recognizer.
TheMessagerecognizersettingsaremirroredontheLocalandTPSinserialports.