Step 2. Set the action.
If the condition is fulfilled, the following action needs to be launched: the receiver sends a command to the
projector over the serial line:
Power on - the required command which is accepted by the projector: PWR0<CR><LF>
For this instance the command has to be closed with the <CR><LF> characters so they need to be escaped.
You can use the following format for escaping:
<command
In the current case the command is: PWR0\x0d\x0a
Select the required parameters to set the action:
Category: RS-232;
Expression: Send RS-232 message;
Port: P1;
Message: PWR0\x0d\x0a
Step 3. Enable the Event.
Select the E1 enabled pipe in upper left corner to set the Event as launched.

INFO:
If you do not find the required category/expression/etc what you need, choose
the Advanced mode in the Wizard where the entire LW3 structure tree is available. For
example instead of signal detection you can set a specified resolution or color range
either as a condition.
><\x0d\x0a><command
><\x0d\x0a>...
1
2
...<command
><\x0d\x0a>
n
Applied firmware packages: (UMX-TPS): v1.5.0b4 | (WP-UMX-TPS): v1.4.0b8 | (FP-UMX-TPS): v1.4.0b8 | LDC software: v2.5.6b2
UMX-TPS-TX100 series – User's Manual
5.11. Settings Menu
5.11.1. Status
The most important hardware and software related information can be found on this tab: hardware and
firmware version, serial numbers, temperatures, operation time, and voltage information. Device label can be
changed to unique description by the Set button.
#serialnumber #miniweb #builtinweb #web

INFO:
The Device label is a user-editable name displayed next to the main menu. The Product name is a read-
only property.
Please note that the Miniweb-related descriptions can be found in
Identify Me Feature
Clicking on the Identify me button results the blinking of the status (in green) for 10 seconds. The feature
helps identifying the device itself in the rack shelf.
Status tab in Settings menu
#label #devicelabel #status #firmwareversion #producttype
The Built-In Miniweb
section.
#identifyme
78

Advertisement

Table of Contents
loading

This manual is also suitable for:

Umx-tps-tx130Umx-tps-tx140Umx-tps-tx140kUmx-tps-tx140-plusFp-umx-tps-tx120Fp-umx-tps-tx130 ... Show all

Table of Contents