The Cec Tool - Lightware UMX-TPS-TX120 User Manual

Hdbaset multimedia extender
Hide thumbs Also See for UMX-TPS-TX120:
Table of Contents

Advertisement

 
5. Software Control - Lightware Device Controller
5.6. The CEC Tool
UMX-TPS-TX140-Plus, UMX-TPS-TX140K and WP-UMX-TPS-TX130-Plus-US models are able to send and
receive Consumer Electronics Control (CEC) commands. This feature is for remote control of the source or
sink device. CEC is a bi-directional communication via HDMI cable, in this case between the input port of the
transmitter and the source.
 #cec
6
Layout of CEC panel on the HDMI input port
The CEC panel is available on the port properties window of the HDMI input and TPS output ports.

ATTENTION!
It can occur that the third-party device can receive, but not execute the command because
it is not supported by the product. Check the accepted commands in the documentation of the device.

INFO:
The first 2x2 bytes of the CEC commands contains identification data of the source and destination
address. When the port is input, it is always 04 (from TV to Playback device 1.)., when the port is output,
it is always 40 (from Playback device 1. to TV).
1
2
3
4
5
Applied firmware packages: (UMX-TPS): v1.5.0b4 | (WP-UMX-TPS): v1.4.0b8 | (FP-UMX-TPS): v1.4.0b8 | LDC software: v2.5.6b2
UMX-TPS-TX100 series – User's Manual
Drop-down
This list contains the basic CEC commands, most of them are displayed on the graphical
1
command
interface, too (on the left side). Click on the Send button to execute sending the command.
list
Custom
The text field is for sending hexadecimal commands to the source. The maximum
2
command
length of the message could be 30 characters (15 bytes). Click on the Send button to
textbox
execute sending the command.
OSD string
A max. 14 character-long text can be shown on the sink device. The send OSD (On-screen
3
textbox
display) command textbox is the input field of the string. Alphanumeric characters,
glyphs and space are accepted. Click on the Send button to execute the command.
Received
Displays all the sent (in red) CEC commands and the received answers (in blue) with a
4
Command
timestamp.
box
Legend of the received message:
< [10:33:17] ACK
Answer for the acknowledged command.
< [10:35:01] NACK
Answer for the not acknowledged command.
< [10:33:17] IN PROGRESS
The command is in progress at the moment.
< [10:33:17] FAILED
Answer for other failure.
< [10:35:40] feature_abort_<*>
This is the most common answer from the third-party devices when the command is
delivered, but the execution is refused. The cause of the refuse stands after 'feature_
abort' expression.
Clear
Click on the Clear button to erase the content of the terminal window.
5
button
CEC
This panel provides the quick and easy management of CEC commands. These buttons
6
command
are pre-programmed with basic functions and sends commands towards the sink.
button
The communication is displayed in the Received Command box. For the list of the
panel
commands see
similar to the design of a remote control.

ATTENTION!
Make sure that the controlled unit is CEC-capable and this function is enabled.
GPIO Port Configuration
section. Both the layout and functionality are
59