Making the Water Connection

Before connecting the water line to the processor, flush the line to remove any debris or rust
particles in the line.
See the Site Specifications, and install the plumbing to the water connection, using an adapter if necessary.

Checking the Drain Valves

Check that the 3 DRAIN VALVES are closed. All VALVE HANDLES should be in the vertical position.
34
CHECK
VALVE
Figure 35 Connecting the Water Inlet Plumbing
SHUTOFF
MIXING
VALVES
VALVE
COLD WATER
SUPPLY
COLD WATER
SUPPLY
HOT WATER
SUPPLY
CIRCUIT
BREAKER
H048_0089DCA
H048_0089DA