Supported Mibs; Snmp Traps; Table 75 Snmpv2 Traps - ZyXEL Communications IES-612-51A User Manual

12-port adsl2/2+ standalone mini-dslam
Hide thumbs Also See for IES-612-51A:
Table of Contents

Advertisement

34.3.1 Supported MIBs

MIBs let administrators collect statistics and monitor status and performance. See
on page 417

34.3.2 SNMP Traps

The IES-612-51A can send the following SNMP traps to an SNMP manager when an event
occurs. ATUC refers to the downstream channel (for traffic going from the IES-612-51A to the
subscriber). ATUR refers to the upstream channel (for traffic coming from the subscriber to
the IES-612-51A).

Table 75 SNMPv2 Traps

TRAP NAME
coldStart
warmStart
linkDown
linkUp
authenticationFailure
reboot
overheat
overheatOver
voltageOutOfRange
voltageNormal
thermalSensorFailure
adslAtucLof
adslAturLof
adslAtucLos
adslAturLos
adslAturLpr
adslAtucLofClear
adslAturLofClear
adslAtucLosClear
adslAturLosClear
adslAturLprClear
IES-612-51A User's Guide
for the list of MIBs the IES-612-51A supports.
DESCRIPTION
This trap is sent when the IES-612-51A is turned on.
This trap is sent when the IES-612-51A restarts.
This trap is sent when the Ethernet link is down. Enterprise specific
(adsl_atuc_los) traps are sent when an ADSL link is down.
This trap is sent when the Ethernet or ADSL link comes up.
This trap is sent when the SNMP community check fails.
This trap is sent when the system is going to reboot. The variable is the
reason for the system reboot.
This trap is sent when the system is overheated. The variable is the
current system temperature in Celsius.
This trap is sent when the system is no longer overheated. The
variable is the current system temperature in Celsius.
This trap is sent when the voltage of the system is out of the normal
range. The variable is the current voltage of the system in volts.
This trap is sent when the voltage of the system is back within the
normal range. The variable is the current voltage of the system in volts.
This trap is sent when the thermal sensor fails.
This trap is sent when a Loss Of Frame is detected on the ATUC.
This trap is sent when a Loss Of Frame is detected on the ATUR.
This trap is sent when a Loss Of Signal is detected on the ATUC.
This trap is sent when a Loss Of Signal is detected on the ATUR.
This trap is sent when a Loss Of Power is detected on the ATUR.
This trap is sent when the Loss Of Frame detected on the ATUC is
over.
This trap is sent when the Loss Of Frame detected on the ATUR is
over.
This trap is sent when the Loss Of Signal detected on the ATUC is
over.
This trap is sent when the Loss Of Signal detected on the ATUR is
over.
This trap is sent when the Loss Of Power detected on the ATUR is
over.