Table 90 Log Messages (continued)
LOG MESSAGE
Sync with timeserver
<ip> failed!
Sync with timeserver
<ip> successful!
Received File <file>!
Received Firmware
Checksum Error!
Received Firmware
Invalid!
Received Firmware Size
too large!
THERMO LOW
VOLTAGE:
dev: <id> limit:
<threshold> value:
<voltage>!
THERMO LOW
TEMPERATURE: dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
THERMO OVER
TEMPERATURE: dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
THERMO OVER
TEMPERATURE released:
dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
THERMO OVER VOLTAGE:
dev: <id> limit:
<threshold> value:
<voltage>!
THERMO OVER VOLTAGE
released:
nominal:<nominal>(mV)
value:<voltage> (mV)!
IES-612-51A User's Guide
TYPE
DESCRIPTION
The device was not able to synchronize the time with the time server at the
WARN
listed IP address.
The device synchronized the time with the time server at the listed IP
INFO
address.
A file was uploaded to the IES-612-51A by FTP.
INFO
<file> - received file's name
A checksum error was detected during an attempted FTP firmware upload.
WARN
Someone attempted to upload a firmware file with a wrong identity via FTP.
WARN
The file size was too large with an attempted FTP firmware upload.
WARN
The device's voltage went above the accepted operating range.
WARN
<id> 1=1.2 V, 2=1.8 V, 3=3.3 V, 4=18 V
<threshold> - voltage limit
<voltage> - voltage of the DC power when logged
The temperature was too low at one of the temperature sensors.
WARN
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip
<threshold> - temperature limit
<temp> - temperature when the entry was logged
The temperature was too high at one of the temperature sensors.
WARN
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip
<threshold> - temperature limit
<temp> - temperature when the entry was logged
The temperature at one of the temperature sensors has come back to
INFO
normal.
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip
<threshold> - temperature limit
<temp> - temperature when the entry was logged
The voltage at one of the voltage sensors went above the accepted
WARN
operating range.
<id> 1=1.2v, 2=1.8v, 3=3.3v, 4=24v
<threshold> - voltage limit
<voltage> - voltage of the DC power when logged
The device's voltage is back inside the accepted operating range.
INFO
<nominal> - nominal voltage of the DC power
<voltage> - voltage of the DC power when logged
Chapter 42 Command Examples
279