14.6 Alarm Profile Screen

Alarm profiles define ADSL port alarm thresholds. The IES-612-51A sends an alarm trap and
generates a syslog entry when the thresholds of the alarm profile are exceeded.
To open this screen, click Basic Setting, xDSL Profiles Setup, Alarm Profile.
Use the top part of the screen (with the Add and Cancel buttons) to add or edit alarm profiles.
The rest of the screen displays the configured alarm profiles.

Figure 59 Alarm Profile

The following table describes the labels in this screen.

Table 27 Alarm Profile

LABEL
Port Profile
VC Profile
IGMP Filter Profile
Name
Add
Cancel
IES-612-51A User's Guide
DESCRIPTION
Click Port Profile to open the Port Profile screen (see
125). Use the Port Profile screen to configure profiles of ADSL port settings
(such as the transfer rate, interleave delay and signal to noise ratio settings).
Click VC Profile to open the VC Profile screen where you can configure virtual
channel profiles (see
Section 14.5 on page
Click IGMP Filter Profile to open the IGMP Filter Profile screen where you can
configure IGMP multicast filter profiles (see
This field is read-only if you click Modify to edit a port profile. Type a name to
identify the alarm profile (you cannot change the name of the DEFVAL profile).
You can use up to 31 ASCII characters; spaces are not allowed.
Click Add to save your changes to the IES-612-51A's volatile memory. The IES-
612-51A loses these changes if it is turned off or loses power, so use the Config
Save link on the navigation panel to save your changes to the non-volatile
memory when you are done configuring.
Click Cancel to start configuring the screen again.
Chapter 14 xDSL Profiles Setup
Section 14.1 on page
131).
Section 14.8 on page
135).