Chapter 40 Alarm
Table 86 Alarm Event Setup Edit (continued)
LABEL
Apply
Close

40.5 Alarm Port Setup Screen

Use this screen to set the alarm severity threshold for recording alarms on an individual
port(s). The system reports an alarm on a port if the alarm has a severity equal to or higher
than the port's threshold.
To open this screen, click Alarm, Alarm Port Setup.

Figure 132 Alarm Port Setup

The following table describes the labels in this screen.

Table 87 Alarm Port Setup

LABEL
Alarm Status
Alarm Event Setup
Port
Severity
Apply
Cancel
254
DESCRIPTION
Click Apply to save your changes to the IES-612-51A's volatile memory. The
IES-612-51A loses these changes if it is turned off or loses power, so use the
Config Save link on the navigation panel to save your changes to the non-
volatile memory when you are done configuring.
Click Close to exit the screen without saving your changes.
DESCRIPTION
Click Alarm Status to go to a screen that displays the alarms that are currently
in the system (see
Section 40.2 on page
Click Alarm Event Setup to go to a screen where you can configure the
severity level of an alarm(s) and where the system is to send the alarm(s). See
Section 40.4 on page
251.
This column lists the device's individual DSL and Ethernet interfaces.
Select an alarm severity level (critical, major, minor or info) as the threshold for
recording alarms on this port. Critical alarms are the most severe, major alarms
are the second most severe, minor alarms are the third most severe and info
alarms are the least severe.
Click Apply to save your changes to the IES-612-51A's volatile memory. The
IES-612-51A loses these changes if it is turned off or loses power, so use the
Config Save link on the navigation panel to save your changes to the non-
volatile memory when you are done configuring.