Pcb Setup - NEC ASPILA EX Feature Manual

Hide thumbs Also See for ASPILA EX:
Table of Contents

Advertisement

10-03 : PCB Setup

Level:
IN
Description
Input Data
Item
No.
01
Terminal Type
02
Logical Port Number
Aspila EX Software Manual
Program 10 : System Configuration Setup
Available.
Use Program 10-03 : PCB Setup to setup and confirm the Basic Configuration data for each PCB.
When changing a defined terminal type, first set the type to '0' and then plug the new device in to
have the system automatically define it, alternatively redefine the type manually.
Program 10-03 allows the editing of installed units (PCB's), you can not edit the settings if the slot
is unused, install the PCB first then edit the settings.
The items highlighted in grey are read only and cannot be changed.
Note:
For ESIU Unit
Physical Port Number
Item
Aspila EX
B-Channel 1
Input Data
0- Not set
1- Keyset/DSLT
2- SLT Adapter
3- -- Not used --
4- -- Not used --
5- -- Not used --
6- PGD (Paging)
7- PGD (Tone Ringer)
8- PGD (Doorbox)
9- PGD (ACI)
10- DSS Console
11- -- Not used --
0: Not set
1: Keyset
2: SLT Adapter
3: Not used
4: Not used
5: 2DCI Adapter 1 - 32
6: PGD (Paging)
7: PGD (for Tone Ringer) 1-8
8: PGD (for Door Box)
9: PGD (for Analogue I/F) 1-96
10: DSS
11: Not used
10-03 : PCB Setup
01-16
1-8
Programming
Default
0
0
421