Item
No.
22
loop disconnect detect minimum time
23
loop disconnect detect maximum time
24
on hook normal detect time
25
on hook reverse detect time
26
on hook disconnect detect time
27
pulse dial break time (10pps)
28
pulse dial make time (10pps)
29
inter-digit time (10pps)
30
pulse dial break time (20pps)
31
pulse dial make time (20pps)
32
inter-digit time (20pps)
Conditions
Feature Cross Reference
Telephone Programming Instructions
Aspila EX Software Manual
Program 81 : Basic Hardware Setup for Trunk
Item
None
Central Office Calls, Placing
To enter data for Program 81-01 (COIU Initial Data Setup):
1.
Enter the programming mode.
2.
81 01
81-01-01
Encoding Type 0: U-LAW
­
¯
back
3.
Enter the number of the item you want to program.
81-01-nn
nnnnn
¬
4.
Enter data for the item you selected + HOLD.
5.
Enter data for the next item in the program.
OR
Press MSG once to enter a new item number.
OR
Press MSG until you've exited that series's programming section.
81-01 : COIU Initial Data Setup
select
®
Input Data
1-255 (8-2040mS)
50 (400ms)
1-255 (8-2040mS)
80 (640ms)
1-255 (8-2040mS)
1-255 (8-2040mS)
1-255 (16-4080mS)
188 (3008ms)
1-255 (4-1020mS)
1-255 (4-1020mS)
1-255 (32-8160mS)
19 (608ms)
1-255 (4-1020mS)
1-255 (4-1020mS)
1-255 (32-8160mS)
16 (512ms)
Programming
Default
3 (24ms)
2 (16ms)
8 (32ms)
4 (16ms)
4 (16ms)
2 (8ms)