CNF(16)-U20 ETU Setup

C N F ( 1 6 ) - U 2 0 E T U

System Requirements

The CNF(16)-U20 ETU is a hot-swappable ETU that can be installed in any
slot in the Electra Elite IPK II KSU. It is recognized by the CPU as a CNF(16)
or CNF(8) ETU.

New firmware may be required for the CPU to recognize the CNF(16)-U20 ETU
and for the CNF(8)-U20 ETU to initialize correctly.
The Ethernet connector can use a Category 5 (CAT5) unshielded twisted pair
(UTP) cable to connect to an Ethernet hub or switch within the customer
premises.
The following steps can be taken to install the CNF(16)-U20 ETU.
1.
Place DIP Switch 3 or 4 on SW1 in the position to select the number of
ports the card supports.
2.
Place DIP Switch 2 on SW1 to ON to configure for simple conference
mode.
3.
Place the CNF(16)-U20 ETU in the desired slot in the Electra Elite IPK II
KSU.
4.
After the DS11-DS13 LEDs (LED1-LED3 on the back of the ETU) are on,
the unit is fully operational.
5.
Connect the Ethernet cable coming from a hub or switch from the
customer premises to the connector on the CNF(16)-U20 ETU. Verify
that the link light is on green.
At this point, the CNF(16)-U20 ETU is physically accessible. Please see the
Chapter 3 CNF(16)-U20 ETU Configuration on page 3-1
the CNF(16)-U20 ETU.
on how to configure
2 - 1