Department Group Pilot Numbers - NEC ASPILA EX Feature Manual

Hide thumbs Also See for ASPILA EX:
Table of Contents

Advertisement

11-07 : Department Group Pilot Numbers

Level:
IN
Description
Input Data
Department (Extension) Group Number
Extension Group
Pilot Number
Dial
(Up to 8 digits)
Default
Conditions
Feature Cross Reference
Aspila EX Software Manual
11-07 : Department Group Pilot Numbers
Available.
Use Program 11-07 : Department Group Pilot Numbers to assign pilot numbers to each Depart-
ment Group set up in Program 16-02. The pilot number is the number users dial for Department
Calling and Department Step Calling. The pilot number can be up to eight digits long. The first/
second digit(p) of the number should be assigned in Program 11-01 as type 2.
Use this program to assign department group
pilot numbers.
The number set up by Program 11-02 (Extension
Numbering) cannot be used.
The extension number cannot be duplicated in
Programs 11-02, 11-04, 11-06 and 11-08.
Group Numbers 01-64: No setting
None
Department Calling
Department Step Calling
Program 11 : System Numbering
Aspila EX
Description
01-64
Related Program
16-01 : Department (Extension)
Group Basic Data Setup
16-02 : Department Group
Assignment for Extensions
16-03 : Secondary Department
Group
Programming
487