Call Progress Tone Detector Setup - NEC ASPILA EX Feature Manual

Hide thumbs Also See for ASPILA EX:
Table of Contents

Advertisement

Program 80 : Basic Hardware Setup for System

80-04 : Call Progress Tone Detector Setup

80-04 : Call Progress Tone Detector Setup
Level:
MF
Description
Input Data
942
Programming
Available.
Use Program 80-04 : Call Progress Tone Detector Setup to define the various levels and timers
for the Call Progress Tone Detector
Tone Detector Type No
Item No.
Item
01
Detect Level
02
Min. detect level
03
S/N ratio
04
No tone time
05
Pulse Count
06
ON min. time
07
ON max. time
08
OFF min. time
09
OFF max. time
10
-- Reserve --
11
-- Reserve --
Aspila EX
1- Dial Tone for Trunk
2- Busy Tone for Trunk
3- Ring Back Tone for Trunk
4- - Reserve -
5- - Reserve -
Input Data
1- 0dBm...-30dBm
2- -15dBm...-45dBm
3- -30dBm...-55dBm
0-15
detect level 0 : –15dBm(0) to –30dBm(15)
detect level 1 : –30dBm(0) to –45dBm(15)
detect level 2 : –40dBm(0) to –55dBm(15)
0-4 (0dB...-20dB)
1-255 (30+30-7650ms)
(0: No detection)
1-255
1-255 (30+30-7650ms)
0-255 (30+30-7650ms)
(0: No detection)
1-255 (30+30-7650ms)
1-255 (30+30-7650ms)
(0: No detection)
0-8
0-8
Aspila EX Software Manual