Advertisement

Item
No.
01
ISDN Line Mode
02
Logical Port Number
(see Note 1)
03
CRC Multi-frame(CRC4)
(Only E1[30B+D] Mode)
04
Layer 3 Timer Type
05
- Not Currently Used -
CLIP Information Announcement
06
Length of a cable
07
S-point DID digits
08
Dial Sending Mode
09
Dial Information Element
(Only for Overlap Sending Mode)
10
Master/Slave System (NW mode only)
11
Networking System Number (NW
mode only)
12
short / long-haul
Aspila EX Software Manual
Program 10 : System Configuration Setup
For PRIU Unit
Item
Input Data
0- Not set
1- Trunk mode
2- S-Bus mode
3- NW mode (Leased Line)
4- NW mode (Interconnected Line)
5- NW Mode (Interconnected Line, Fixed Layer 1=NT)
6- S-Point (Leased Line)
1: for Trunk mode 1-200
2: for S-Bus 1-256
0- off
1- on
1-5
0- disable
1- enable
0- 0 40m
1- 40 81m
2- 81 122m
3- 122 162m
4- 162 200m
0-4
0- Enblock Sending
1- Overlap Sending
0- Keypad Facility
1- Called Party Number
0- Slave System
1- Master System
0-50
0- short-haul
1- long-haul
10-03 : PCB Setup
Default
Programming
1
0
0
1
1
0
0
1
1
0
0
0
425