Honda CBR600F4i Series Service Manual page 443

Hide thumbs Also See for CBR600F4i Series:
Table of Contents

Advertisement

IGNITION SYSTEM
Avoid
touching
the
sf)ilrk
pluos
and
1esrer
probes
ro
prevem
electric
shock·.
Connect the peak voltage
tester
or
peak
voltage adap-
tor
probes
to
the
connector terminal of
the
w
ire
h
ar-
ness side and
ground.
TOOLS:
Peak voltage tester
(U.S.A.
only} or
Peak voltage adaptor
07HGJ-0020100
(not
available
in
U.S.A.)
with commercially
available
digital multimeter
(impedance
10
M Q/DCV
minim
um)
CONNECTION:
Yellow
terminal
(+)
-
Ground
(-}
Cronk the engine
with
the starter
motor
ond
reod
the
peak
voltaqe.
PEAK
VOLTAGE:
0.7
V
minimum
If
the peak voltage measured at
ECM
m
ulti-connector
is abnormal, measure
the
peak voltage
Rt
the
igniti
on
pulse generator connector.
Disr.onrn~r.t the ignition pulse generator
2P
(Red)
con-
nector
and connect the tester probes
to
the
termi
nal
(Yellow and White/Yellow)
.
In
the
same
manner
as
at
t he
ECM
connector,
mea-
sure
the
peak
voltage and compare it to
the
voltage
measured at the
ECM
connector.
If
the
peak
voltage
measured
at
the
ECM
is ahnor-
mal
and
the
one
measured
at the ignition pulse
yemnatu
r
is
norma
l,
the wire harness
has
an open
r.irr.uit
or loose
connection.
If both peok voltoges are abnormal, check each item
in
the t roubleshooting chart. If
all
items are
normal,
the
ignit
ion
pulse
generator is faulty.
See
following
steps
for
ignition pulse generator
repl11r.emP.nt
.
IGNITION PULSE GENERATOR
REMOVAL
17-6
Remove the lower
cowl
(page
2-4).
Disconnect
the
ignition pulse generator
2P
(Red) con
necto1.
PEAK
VOLTAGE ADAPTOR
PEAK
VOLTAG
E
ADAPTOR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbr600f4i 2001Cbr600f4i 2002Cbr600f4i 2003

Table of Contents