FUEL SYSTEM (Programmed Fuel Injection)
Check for
contin
uity
between the No.4
injector
and ground.
Connection:
Black/White
(+}
-
Ground
H
Standard:
No
continuity
No continuity
Turn the ignition
switch
to
"ON".
Measu
re
Lhe
voltafle
between
the No.4
inject
or
r.onnP.r.tor
of
the
w ire
harness side
and
ground.
Connection:
Black/White
(+}
-
Ground
H
Standard: Battery
voltage
Voltage P-xists
Turn
the
ig
nition
switr.h to "OFF".
Connect
the No.4 injector
connector.
5-36
Continuity
Out of
range
• Faulty No.4
injector.
•
Open or
sho
rt
cirt:uit
in
Black/White
wire.