Diagnostics Via Starter; Diagnostic Functions - Siemens SINAMICS Series Operating Instructions Manual

Hide thumbs Also See for SINAMICS Series:
Table of Contents

Advertisement

Descriptions of functions
10.34 Diagnostics
LED
Color
OPT
-
(OPTION)
Green
Red
RDY and
Red
DP1
RDY and
Orange
OPT
MOD
-
10.34.5

Diagnostics via STARTER

The diagnostic functions support commissioning and service personnel during
commissioning, troubleshooting, diagnostics and service activities.
Requirement
● Online operation of the STARTER commissioning tool.

Diagnostic functions

The following diagnostic functions are available in the STARTER commissioning tool:
● Specification of signals with the ramp-function generator
● Signal recording with the trace function
● Analysis of the control response with the measuring function
638
State
Description, cause
Off
Electronic power supply is missing or outside
permissible tolerance range,
Component not ready for operation,
Option Board not installed,
No associated drive object has been created
Continuous
Option Board is ready for operation.
light
Flashing light
Depends on the Option Board used
0.5 Hz
Flashing light
At least one fault is present in this component.
2 Hz
Option board not ready (e.g. after switching on)
Flashing light
Bus fault – communication has been interrupted
2 Hz
Flashing light
The firmware of the connected CBE20
0.5 Hz
Communication Board Ethernet is being updated
Off
Reserved
Remedy
Check power supply
and/or component
-
-
Remedy and acknowledge
fault
Correct fault
-
-
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A

Advertisement