X520 Encoder System Interface - Siemens SINAMICS Series Operating Instructions Manual

Hide thumbs Also See for SINAMICS Series:
Table of Contents

Advertisement

Additional system components
7.2 SMC10 Sensor Module Cabinet-Mounted
7.2.2.4

X520 encoder system interface

Table 7- 8
Connector
Connector type: 25-pin SUB D connector
Measuring current via temperature sensor connection: 2 mA
200
X520: Encoder system interface
Pin
Signal name
1
Reserved, do not use
2
Reserved, do not use
3
S2
4
S4
5
Ground
6
S1
7
S3
8
Ground
9
R1
10
Reserved, do not use
11
R2
12
Reserved, do not use
13
-
14
Reserved, do not use
15
Reserved, do not use
16
Reserved, do not use
17
Reserved, do not use
18
Reserved, do not use
19
Reserved, do not use
20
Reserved, do not use
21
Reserved, do not use
22
Reserved, do not use
23
Reserved, do not use
24
Ground
25
-
Technical data
Resolver signal A (sin+)
Inverted resolver signal A (sin-)
Ground (for internal shield)
Resolver signal B (cos+)
Inverted resolver signal B (cos-)
Ground (for internal shield)
Resolver excitation positive
Resolver excitation negative
Ground (for internal shield)
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A