Parameterizing telegram (SetPrm)
The filter table is transferred, as a dedicated block from the master to the slave with the
parameterizing telegram when a bus communication is established.
Figure 10-18 Filter block in the parameterizing telegram (SetPrm)
Configuration telegram (ChkCfg)
Using the configuration telegram, a slave knows how many setpoints are to be received from
the master and how many actual values are to be sent to the master.
For direct data exchange, a special space ID is required for each tap. The PROFIBUS
configuration tool (e.g. HW Config) generates this ID. The ID is then transferred with the
ChkCfg into the drive devices that operate as subscribers.
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
Descriptions of functions
10.4 Communication via PROFIBUS DP