Receive process data
DWORD
connector output
WORD connector
output
Binector output
Free binector-
connector
converter
Send process data
DWORD
connector input
WORD connector
input
Free connector-
binector converter
Notes on telegram interconnections
● When you change p0922 = 999 (factory setting) to p0922 ≠ 999, the telegrams are
interconnected and blocked automatically.
● Exceptions to this are the telegrams 20, 220, and 352. Here, selected PZDs can be
interconnected as required in the send/receive telegram.
● When you change p0922 ≠ 999 to p0922 = 999, the previous telegram interconnection is
retained and can be changed.
● If p0922 = 999, a telegram can be selected in p2079. A telegram interconnection is
automatically made and blocked. The telegram can also be extended.
This is an easy method for creating extended telegram interconnections on the basis of
existing telegrams.
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
DC_CTRL
CU_DC
r2060[0 ... 62]
-
r2050[0 ... 63]
r2050[0 ... 19]
r2090.0 ... 15
r2091.0 ... 15
r2092.0 ... 15
r2093.0 ... 15
p2080[0 ... 15], p2081[0 ... 15], p2082[0 ... 15], p2083[0 ... 15],
p2084[0...15] / r2089[0 ... 4]
p2061[0 ... 62]
-
p2051[0 ... 63]
p2051[0 ... 24]
p2099[0 ... 1] / r2094.0 ... 15, r2095.0 ... 15
Descriptions of functions
10.3 Communication according to PROFIdrive
TM31,
TM15DI_DO,
TM150
-
r2050[0 ... 4]
r2090.0 ... 15
r2091.0 ... 15
-
p2051[0 ... 4]
ENCODER
r2060[0 ... 2]
r2050[0 ... 3]
r2090.0 ... 15
r2091.0 ... 15
r2092.0 ... 15
r2093.0 ... 15
p2061[0 ... 10]
p2051[0 ... 11]
411