Siemens SINAMICS Series Operating Instructions Manual page 587

Hide thumbs Also See for SINAMICS Series:
Table of Contents

Advertisement

y ...
x ...
Figure 10-68 I
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
10.20 Thermal overload protection for the DC motor (I2t monitoring of the motor)
Load current/permissible continuous current (p50100 × p50113)
Time/thermal time constant of motor
t monitoring of the motor: Fault triggering
2
Descriptions of functions
585