Maintenance
11.1 Upgrading firmware releases
11.1.2
Upgrading the DCC technology option
Step 5: Update the DCC technology option (DCBLIB) and the DCC charts
It is not absolutely necessary to upgrade the DCC library. Only upgrade the DCC library if
you wish to use functions that the old DCC library does not support.
It is only possible to upgrade the DCC library via the associated STARTER project. While
upgrading, it is not permissible that there is a DCC chart in the drive.
After you have upgraded the unit firmware according to the previous chapter, update the
DCC technology option as follows:
● Establish a connection to the drive using STARTER.
● Delete the parameter assignment and DCC charts in the drive, by setting p0976 to 200.
After deleting, the parameterization including the DCC charts only exist in STARTER.
● After the system was reset via p0967 = 200, re-establish a connection to the drive via
STARTER.
● Import the new DCC library (see Chapter "Drive Control Chart (DCC) (Page 663)")
Figure 11-1
● Carry out a POWER OFF / POWER ON to activate the new DCC library.