Siemens SINAMICS Series Operating Instructions Manual page 610

Hide thumbs Also See for SINAMICS Series:
Table of Contents

Advertisement

Descriptions of functions
10.28 Connecting units in parallel and in series
Table 10- 71 6-pulse parallel connection n+m operation
Parameter
p51799
Operating principle
p51800
Position in the topology
p51801
Number of send data
p51802
Minimum number of nodes n
p51812
Total number of nodes
p51803
n+m mode
p51804[..]
Transmit data
p51805
Bus terminator
p51806
Station address
p51807
Telegram failure time
p50082
Field operating mode
p50076[..]
Reduction in rated unit DC
current
p50078[..]
Rated value for supply
voltage
p50100
Rated motor current
p50110
Armature resistance Ra
p50111
Armature inductance La
p50114
Motor thermal time
constant
p50140
Motor I
t monitoring,
2
response when starting
p50115 to
Field characteristic
p50139
p51591
La reduction factor
p50357
Threshold for interrupted
tachometer
= 1 at the two outermost units (= at the physical ends of the bus line)
1)
= 0 on all of the other units
The optimization run for current controller and precontrol (p50051 = 23 or 25) sets the correct values for these
2)
parameters.
608
Master
0
11 (Master)
Any
n+m
1 (only armature)
2 (armature + field)
Any
0 or 1
1)
Unique address
0.1 s
≠ 0
-
-
Rated motor
current/number of
SINAMICS DCM
Actual armature
2)
resistance × number of
SINAMICS DCM
Actual armature
2)
inductance × number of
SINAMICS DCM
Motor thermal time
constant in s
Application-specific
-
-
2)
Application-specific
Substitute master
The same as at the
master
13 (Substitute master)
Any
The same as at the
master
The same as at the
master
The same as at the
master
Any
0 or 1
1)
Unique address
0.1 s
0 (if only armature)
≠ 0 (if armature + field)
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
(only if n+ m operation for
armature + field)
The same as at the
master
The same as at the
master
Operating Instructions, 12/2018, A5E34763375A
Slave
The same as at the
master
12 (Slave)
Any
The same as at the
master
The same as at the
master
0
Any
0 or 1
1)
Unique address
0.1 s
0 (no field)
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
The same as at the
master
100% (tachometer
interruption monitoring
not active)
SINAMICS DCM DC Converter

Advertisement

Table of Contents
loading

Table of Contents