Field
Format
Number of values
Error values
Values
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
Data type
Unsigned8
The format and number specify the adjoining space containing values in the telegram.
For write access, it is preferable to specify data types according to the PROFIdrive profile.
Bytes, words and double words are also possible as a substitute.
Unsigned8
Specifies the number of subsequent values.
Unsigned16
The error values in the event of a negative response.
If the values make up an odd number of bytes, a zero byte is attached. This ensures the
integrity of the word structure of the telegram.
Unsigned16
The values of the parameter for read or write access.
If the values make up an odd number of bytes, a zero byte is attached. This ensures the
integrity of the word structure of the telegram.
10.3 Communication according to PROFIdrive
Values
Remark
0x02
Data type integer8
0x03
Data type integer16
0x04
Data type integer32
0x05
Data type unsigned8
0x06
Data type unsigned16
0x07
Data type unsigned32
0x08
Data type floating point
Other values
See PROFIdrive profile V3.1
0x40
Zero (without values as a positive
subresponse to a write request)
0x41
Byte
0x42
Word
0x43
Double word
0x44
Error
0x00 ... 0xEA
No. 0 ... 234
Limited by DPV1 telegram length
0x0000 ... 0x00FF
Significance of the error values
→ refer to the following table "Error
values in the DPV1 parameter
responses"
0x0000 ... 0x00FF
Descriptions of functions