Siemens SINAMICS Series Operating Instructions Manual page 55

Hide thumbs Also See for SINAMICS Series:
Table of Contents

Advertisement

Table 4- 16
Technical data for 3-ph. 575 V AC, 60 A to 210 A, 2Q devices
Article number 6RA80 ..
Rated DC current
Rated armature input current
Rated power
Power loss at rated DC current (approx.)
Rated field DC current
Type of cooling
Rated fan supply voltage
Fan air flow
Fan noise level
Dimensions (WxHxD)
Weight (approx.)
Rated DC voltage for single-phase
operation
Rated DC current for
single-phase operation
Table 4- 17
Technical data for 3-ph. 575 V AC, 400 A to 1100 A, 2Q devices
Article number 6RA80 ..
Rated armature input current
Rated power
Power loss at rated DC current (approx.)
Rated field DC current
Type of cooling
Rated fan supply voltage
Rated fan current
Rated fan current
with option L21
Fan air flow
Fan noise level
Dimensions (WxHxD)
Weight (approx.)
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
..25-6GS22-...
A
A
2)
kW
W
A
Self-ventilated
V
m
/h
3
dB(A)
mm
kg
V
A
..81-6GS22-...
A
A
2)
kW
W
A
ventilation
50 Hz
V
3-ph. 400 V AC
clockwise phase
sequence
60 Hz
V
3-ph. 460 V AC
clockwise phase
sequence
50 Hz
A
60 Hz
50 Hz
A
60 Hz
m
/h
3
50 Hz
dB(A)
60 Hz
mm
268x625x275
kg
..31-6GS22-...
60
49.8
41.4
274
10
Self-ventilated
-
-
-
268x385x252
268x385x252
11
460
42.0
..85-6GS22-...
400
600
332
498
276
414
1598
2002
25
25
Forced
Forced
ventilation
3-ph. 400 V AC
(±15%)
(±15%)
clockwise phase
sequence
3-ph. 460 V AC
(±10%)
(±10%)
clockwise phase
sequence
With option L21: 1-ph. 230 V AC (±10%)
0.27
0.27
8)
8)
0.33
0.33
0.68
0.68
0.95
0.95
600
600
70.3
70.3
74.4
74.4
268x625x275
26
28
Technical data
4.5 Unit data
..75-6GS22-...
125
210
104
174
86.3
145
463
742
10
Forced ventilation
-
Fan with internal
power supply
-
300
-
70.3
268x385x252
14
460
87.5
..87-6GS22-...
..90-6GS22-...
800
664
552
2686
30
Forced
ventilation
ventilation
3-ph. 400 V AC
3-ph. 400 V AC
(±15%)
clockwise phase
clockwise phase
sequence
sequence
3-ph. 460 V AC
3-ph. 460 V AC
(±10%)
clockwise phase
clockwise phase
sequence
sequence
0.27
8)
0.33
0.68
0.95
600
70.3
74.4
268x700x311
268x785x435
38
15
14
-
-
1100
913
759
4022
40
Forced
(±10%)
(±10%)
0.38
9)
0.5
1.16
1.7
1000
70.4
74.2
78
53

Advertisement

Table of Contents
loading

Table of Contents