Communication Channels For Profinet; Drive Control With Profinet; Profinet Interfaces - Siemens SINAMICS Series Operating Instructions Manual

Hide thumbs Also See for SINAMICS Series:
Table of Contents

Advertisement

Descriptions of functions
10.5 Communication via PROFINET IO
10.5.2.4

Communication channels for PROFINET

Control Unit with CBE20 Communication Board Ethernet
A Communication Board can be optionally inserted in the Control Unit CUD:
● The CBE20 Communication Board is a PROFINET switch with four PROFINET ports.
Overview of important parameters
(See the SINAMICS DCM List Manual)
• p8829
• p8940[0...239]
• p8941[0...3]
• p8942[0...3]
• p8943[0...3]
• p8944
• p8945
• r8950[0...239]
• r8951[0...3]
• r8952[0...3]
• r8953[0...3]
• r8954
• r8955[0...5]
• r8959
10.5.3

Drive control with PROFINET

PROFINET interfaces

The CBE20 Communication Board Ethernet can be inserted in the option slot of a CUD. The
Communication Board Ethernet CBE20 is a PROFINET switch with four ports.
Note
Ring topology
When connecting the ports, it must be ensured that for standard applications a ring topology
is not created. Additional information on ring topologies can be found in Chapter "Media
redundancy (Page 499)".
496
CBE20 remote controller number
CBE20 name of station
CBE20 IP address of station
CBE20 default gateway of station
CBE20 subnet mask of station
CBE20 DHCP mode
CBE20 interface configuration
CBE20 name of active station
CBE20 IP address of active station
CBE20 default gateway of active station
CBE20 subnet mask of active station
CBE20 DHCP mode active
CBE20 MAC address of station
CBE20 DAP ID
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A

Advertisement

Table of Contents
loading

Table of Contents