Installing Gsdml; Activating Diagnostics Via The Control; Profienergy - Siemens SINAMICS G110M Function Manual

Fieldbus systems
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

3.6.3.3

Installing GSDML

Procedure
1. Save the GSDML to your PC.
– With Internet access:
– Without Internet access:
2. Unzip the GSDML file on your computer.
3. Import the GSDML into the engineering system of the controller.
You have now installed the GSDML in the engineering system of the controller.
3.6.3.4

Activating diagnostics via the control

The converter provides the functionality to transmit fault and alarm messages (diagnostic
messages) to the higher-level control according to the PROFIdrive error classes.
The functionality must be selected in the higher-level controller and activated by powering
up.
3.6.4

PROFIenergy

PROFIenergy is an energy management standard for production plants, based on the
PROFINET communication protocol. The functionality is certified and described in the
PROFIenergy profile of the PNO.
The control transfers the PROFIenergy commands in acyclic operation to the inverter in data
set 80A0 hex.
The inverters support the PROFIenergy profile V1.1 and the function unit class 3.
Parameters r5600 to p5614 are reserved for PROFIenergy functions in the inverter.
An application example for energy savings with PROFIenergy is available in the Internet at:
PROFIenergy - saving energy with SIMATIC S7
(https://support.industry.siemens.com/cs/ww/en/view/41986454)
Fieldbuses
Function Manual, 04/2018, FW V4.7 SP10, A5E34229197B AE
GSDML (https://support.industry.siemens.com/cs/ww/en/ps/13222/dl)
Insert a memory card into the inverter.
Set p0804 = 12.
The inverter writes the GSDML as zipped file (*.zip) into directory
/SIEMENS/SINAMICS/DATA/CFG on the memory card.
Communication via PROFIBUS and PROFINET
3.6 Communication via PROFINET
65