Technical data
4.2 Duty cycles for 2Q applications
Note
• If a value > 1 is set at p50067, you need to make sure that the "Dynamic overload
capability of the power unit" is enabled. This requires a value > 0 to be set at p50075.
• The SINAMICS DC MASTER does not monitor whether the load class set using p50067
is being adhered to. If the power unit permits it, longer overload periods can be used than
those that correspond to the load class.
The actual permissible overload duration for the particular power unit is always greater
than the overload duration corresponding to the particular load class. SINAMICS DC
MASTER monitors whether the overload duration that is actually permitted for the power
unit is being maintained. For details on the power unit's dynamic overload capability, refer
to Chapter "Dynamic overload capability of the power unit (Page 591)".
• The 100% I
but are reduced according to the subsequent table.
4.2
Duty cycles for 2Q applications
Table 4- 2
Duty cycles for 2Q applications
SINAMICS
DCM
Tu
continuous
°C
6RA80..
400 V, 2Q
.25-6DS22
45
60
.28-6DS22
45
90
.31-6DS22
45
125
.75-6DS22
40
210
.78-6DS22
40
280
.81-6DS22
40
400
.85-6DS22
40
600
.87-6DS22
40
850
.91-6DS22
40
1200
.93-4DS22
40
1600
.95-4DS22
40
2000
.98-4DS22
40
3000
40
shown previously DO NOT generally correspond to the rated unit current,
DCx
DC I
DC II
15 min
60 s
100%
150%
A
A
A
51.4
77.1
74.4
111
106
159
164
247
226
340
290
435
462
693
652
978
884
1326
1255
1883
1477
2216
2288
3432
Duty cycles
DC III
15 min
120 s
15 min
100%
150%
100%
A
A
50.2
75.3
46.4
72.8
109
65.4
103
155
96.3
161
242
136
219
328
201
282
423
244
446
669
413
622
933
609
857
1286
768
1213
1819
1139
1435
2152
1326
2189
3283
2164
Operating Instructions, 12/2018, A5E34763375A
DC IV
US rating
Tu = 45 °C
10 s
15 min
200%
100%
A
A
A
92.8
51.4
130
74.4
192
106
273
157
402
215
488
278
826
443
1219
619
1537
842
2279
1190
2653
1404
4328
2178
SINAMICS DCM DC Converter
60 s
150%
A
77.1
111
159
236
323
417
665
929
1263
1785
2106
3267