3-ph. 830 V AC, 2Q devices
6RA8088-6LS22-0AA0
Table 4- 22
Technical data for 3-ph. 830 V AC, 2Q devices
Common data
Rated armature supply voltage
Rated field supply voltage
Electronic power supply,
rated supply voltage
Rated DC voltage
1)
Rated field DC voltage
1)
Rated frequency
Overload possibility
6)
Closed-loop control constancy
Degree of protection
Protection class
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
6RA8093-4LS22-0AA0
V
3-ph. 830 V AC (+10% / -20%)
1)
V
2-ph. 480 V AC (+10% / -20%)
1)
V
2 AC 380 (-25%) to 480 V AC (+10%); In = 1 A or
1 AC 190 (-25%) to 240 V AC (+10%); In = 2 A
(-35% for 1min.)
With option L05: 18 to 30 DC; In = 5 A
V
1000
V
390
Hz
45 to 65
Max. 1.8x rated DC current
Δn = 0.006% of the rated motor speed during operation with
incremental encoder and digital setpoint
Δn = 0.1% of the rated motor speed during operation with
analog tachometer or analog setpoint
IP00 according to EN 60529
Class I (with protective conductor system) and class III (PELV)
according to EN 61800-5-1