7.3 Sensor Module Cabinet-Mounted SMC30
7.3.3.2
X500 DRIVE-CLiQ interface
Table 7- 13
Connector
Connector type: DRIVE-CLiQ socket
The blanking cover for the DRIVE-CLiQ port is included in the scope of supply.
Blanking covers (50 x) Article No.: 6SL3066-4CA00-0AA0
7.3.3.3
X524 electronic power supply
Table 7- 14
Connector
Type: Screw terminal
Conductor cross sections that can be connected: Flexible, 0.08 mm
Stripped length: 8 to 9 mm
Tool: 0.4 × 2.0 mm screwdriver
The maximum cable length that can be connected is 30 m.
Note
The two "+" or "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
210
DRIVE-CLiQ interface X500
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
Reserved, do not use
B
M (0 V)
X524 terminal strip
Terminal
Function
+
Electronic power supply
+
Electronic power supply
M
Electronics ground
M
Electronics ground
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Electronics ground
Technical specifications
Voltage: 24 V (20.4 – 28.8 V)
Power consumption: Max. 0.55 A
Max. current via the jumper in the
connector: 20 A (15 A according to UL/CSA)